Product Reliability Qualification

 
 
   
  Package
Reliability
Pre-Condition (for SMD package):
    TCT 10cycles + Bake125℃ 24hrs + Soak
    30℃/60% RH 192hrs + IR flow 260℃ 3cycles
  TCT (Temperature Cycle Test):
    -65℃(15min) ~ 150℃(15min), 500 cycles
     
 
 
   
  PCT (Pressure Cooker Test):
    121℃, 100% RH, 2 atm, 168 hrs
     
  THT (Temperature Humidity Test):
    85℃ / 85% RH, 1000 hrs
  HTST (High temperature Storage
    Life Test): 150℃,1000 hrs
   
 
    IC Reliability
       
    HOLT (High temperature Operation Life Test):
      85℃ or 125℃ 500/1000 hrs
    ESD (HBM, MM)
       
    Latch-Up